 | J.D.S. MicroProcessing Technical Bulletin ------------------------------------------------------------------------ Date Written: 08/02/89 Submitted by: R. SANDE Sequence: 1 of 1 FileID: 4.TB006 ------------------------------------------------------------------------ MISSING CHANNEL+DEV END / INTERRUPT PENDING ----------------------------------------------------------------------------- Missing Channel and Device End (or Interrupt Pending) - Indicates that the unit attached failed to present a reply to a time-out or intervention state on the channel.
When this occurs, the DOS/VSE Supervisor (or system nucleus) then presents the message on the operator console. It is possible to use the Hydra-II "FORCE STAT 04" to generate an artificial device end to the channel in order to restore normal operations.
Note: there is no equivelant "FORCE STAT" command on either HYDRA-SNA or HYDRA-3000 Systems.
Under certain circumstances (usually VSE systems) an error of this nature would take the system down to a screeching halt. It is a deteriorating type of error and left untreated will worsen as processing cycles continue.
|
 |
 |
|


 |
 |
 |