22


TB020  HYDRA-II SUPPORT SOFTWARE TAPE RELEASE (B)

 
                 J.D.S. MICROPROCESSING TECHNICAL BULLETIN
------------------------------------------------------------------------
DATE WRITTEN:  08/08/91                    SUBMITTED BY:  R. SANDE
     SEQUENCE:  1 OF 1                            FILEID: TB020 BULLETIN
------------------------------------------------------------------------
              HYDRA-II SUPPORT SOFTWARE TAPE RELEASE (B)
              ==========================================

* THE FORMAT OF THIS TAPE IS:
*
* FILE 0  -  INSTRUCTION FILE.
*            80 X 80 LIST OF THESE INSTRUCTIONS.
*
* FILE 1  -  CMS FORMAT - CONTAINS ALL REQUIRED MEMBERS FOR
*            CMS USERS.
*
*            THIS FILE WAS CREATED USING THE 'VMFPLC2 DUMP' FUNCTION
*            FOR THE FOLLOWING MEMBERS:
*
*            THE TAPE CAN BE USED WITH THE COMMANDS PROVIDED BELOW.
*            (CUU REPRESENTS THE REAL CHANNEL ADDRESS OF THE TAPE DRIVE
*            TAPE FSF
*            CP ATT CUU * 181
*            VMFPLC2 LOAD * *
*
*               HYDRAUTL ASSEMBLE  -  (HYDRAUTL SOURCE PROGRAM)
*               HYDRAUTL MODULE    -  (HYDRAUTL EXECUTABLE)
*               HYDRAUTL TEXT      -  (HYDRAUTL OBJECT MODULE)
*               HYDRA    TDF5      -  (TERMINAL DEFINITIONS FOR HYDRA
*                                     V=5,V=6,V=8,V=9  (4-CHAR FORMAT))
*               HYDRA    TDF4      -  (TERMINAL DEFINITIONS FOR
*                                     HYDRA V=1 TO V=4 (1-CHAR FORMAT))
*               HYDRAORG 4PT       -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 4 PORT SYSTEMS - V=8 & V=9)
*               HYDRAORG 8PT       -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 8 PORT SYSTEMS - V=8 & V=9)
*               HYDRAORG 16PT      -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 16,32,64 PORT SYSTEMS - V=8
*                                     AND V=9)
*               HY100    ASSEMBLE  -  (HY100 SUBROUTINE SOURCE)
*               HY100    TEXT      -  (HY100 OBJECT MODULE)
*               HYMAP    COPY      -  (HYMAP COPY BOOK FOR HY100)
*               HYDRA    KEYMAP    -  (KEYBOARD MAPS AVAILABLE
*                                     FOR STANDARD TDF'S)
*
* FILE 2  -  VSE FORMAT - CONTAINS ALL REQUIRED MEMBERS FOR
*            VSE USERS BLOCKED 80 X 12000 (150 RECORDS PER BLOCK).
*            USE DITTO FOR REBLOCKING : TTR,CUU,CUU,80,1
*            WHERE CUU REPRESENTS THE ADDRESSES OF THE 2 TAPE DRIVES
*
*            AFTER REBLOCKING, THE JCL BELOW CATALOGS THE
*            MEMBERS. NOTE: DIFFERENT JCL'S ARE REQUIRED FOR VSE/SP &
*            DOS/VSE SYSTEMS.
*            (CUU REPRESENTS THE CHANNEL ADDRESS OF THE TAPE DRIVE)
*            (LIBRARY REPRESENTS THE DOS/VSE LIBRARY NAME)
*            (LIB & SUBLIB REPRESENT THE VSE/SP LIBRARY & SUB-LIBRARY)
*
*            (DOS/VSE FORMAT:)
*   // JOB CATUTIL
*   // ASSGN SYSIPT,CUU
*   // LIBDEF SL,TO=LIBRARY
*   // LIBDEF RL,TO=LIBRARY
*   // EXEC MAINT
*   /&
*
*            (VSE/SP FORMAT:)
*   // JOB CATUTIL
*   // ASSGN SYSIPT,CUU
*   // EXEC LIBR,PARM='ACCESS SUBLIB=LIB.SUBLIB'
*   /&
*
*            THE FOLLOWING MEMBERS WILL BE CATALOGED:
*            SOURCE:
*
*               A.HYDRAUTL         -  (HYDRAUTL SOURCE PROGRAM)
*               D.HYDRAV5          -  (TERMINAL DEFINITIONS FOR HYDRA
*                                     V=5,V=6,V=8,V=9  (4-CHAR FORMAT))
*               D.HYDRAV4          -  (TERMINAL DEFINITIONS FOR
*                                     HYDRA V=1 TO V=4 (1-CHAR FORMAT))
*               D.HYORG4           -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 4 PORT SYSTEMS - V=8 & V=9)
*               D.HYORG8           -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 8 PORT SYSTEMS - V=8 & V=9)
*               D.HYORG16          -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 16,32,64 PORT SYSTEMS - V=8
*                                     AND V=9)
*               A.HY100            -  (HY100 SUBROUTINE SOURCE)
*               A.HYMAP            -  (HYMAP COPY BOOK FOR HY100)
*               D.HYKEYMAP         -  (KEYBOARD MAPS AVAILABLE
*                                     FOR STANDARD TDF'S)
*
*            RELO:
*               HYDRAUTL           -  (HYDRAUTL OBJECT MODULE)
*
* FILE 3  -  OS/MVS FORMAT - CONTAINS ALL REQUIRED MEMBERS FOR
*            OS/MVS USERS BLOCKED 80 X 12000 (150 RECORDS PER BLOCK)
*
*            THE JCL BELOW CATALOGS THE MEMBERS TO A LIBRARY.
*            (LIBRARY REPRESENTS THE DATA SET NAME FOR HYDRA FILES)
*            (VOL=SER=PACK REPRESENTS THE VOLID OF THE LIBRARY'S DASD)
*
*     //GETUTIL  JOB
*     //S1       EXEC PGM=IEBUPDTE,PARM=NEW
*     //SYSPRINT DD SYSOUT=A
*     //SYSIN    DD DSN=FILE4,DISP=(OLD,KEEP),
*     //            UNIT=TAPE,
*     //            VOL=SER=HYDRA1,LABEL=(4,NL),
*     //            DCB=(LRECL=80,BLKSIZE=12000,RECFM=FB)
*     //SYSUT2   DD DSN=LIBRARY
*     //            UNIT=SYSDA,VOL=SER=PACK,
*     //            SPACE=(TRK,(15,15,5)),
*     //            DISP=(NEW,CATLG,DELETE),
*     //            DCB=(LRECL=80,BLKSIZE=6160,RECFM=FB,DSORG=PO)
*
*     THE FOLLOWING MEMBERS WILL BE CATALOGED:
*
*               HYDRAUTL         -  (HYDRAUTL SOURCE PROGRAM)
*               NOTE:HYDRAUTL MUST BE ASSEMBLED BY USER
*
*               HYDRAV5          -  (TERMINAL DEFINITIONS FOR HYDRA
*                                     V=5,V=6,V=8,V=9  (4-CHAR FORMAT))
*               HYDRAV4          -  (TERMINAL DEFINITIONS FOR
*                                     HYDRA V=1 TO V=4 (1-CHAR FORMAT))
*               HYORG4           -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 4 PORT SYSTEMS - V=8 & V=9)
*               HYORG8           -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 8 PORT SYSTEMS - V=8 & V=9)
*               HYORG16          -  (HYDRA ORIGINAL FACTORY CONFIG
*                                     FOR 16,32,64 PORT SYSTEMS - V=8
*                                     AND V=9)
*               HY100            -  (HY100 SUBROUTINE SOURCE)
*               HYMAP            -  (HYMAP COPY BOOK FOR HY100)
*               NOTE:HY100 MUST BE ASSEMBLED BY USER
*
*               HYKEYMAP         -  (KEYBOARD MAPS AVAILABLE
*                                   FOR STANDARD TDF'S)
*
* FILE 4  -  FIVE TAPE MARKS.
*
* THE CURRENT SOFTWARE VERSIONS ON THIS TAPE ARE:
* HY100 / HYMAP - 3.2
* HYDRAUTL - 1.47