209


PROG: H3000 Module Status (MS) Debugger Command
 
The module status debugger command is used to determine the microcode integrity of the entire HYDRA 3000 system. Each module has a unique checksum number when loaded into memory. If the checksum is correct the modules will be listed similar to the screens below. (Please note: the numbers have no meaning to the user, but indicate a healthy module) If there is ever a problem with a particular piece of microcode, H3000 will flag the offending entry with an error message. The user can execute the kill module "KILM" diagnostic and simply reload that portion of code without having to reload the entire box.

68010 Microprocessor Based Unit

FAT:MS
BC 0079 007FAD6D - Master Processor (Bus Controller)
CC 0060 005CA79B - Channel Controller Board
CF 0017 002E2FA5 - H3000UTL Control File
NC 0060 005CA79B - Network Controller Board (token-ring etc.)
PA 0008 00083B99 - ...................File System, TDF's Etc..
PC 00A1 00A5D405 - Port Controller (Async Interface)
PE 0007 0007117F - ...................File System, TDF's Etc..
P1 0005 0004A2DF - ...................File System, TDF's Etc..

** 0069 <<BLOCKS FREE



68030 Microprocessor Based Unit

FAT:MS
AE 004A 0049635B - Async Interface Code
AM 0051 0055F540 - Async Interface Code
CE 0060 0060B05D - Channel Interface Code
CF 0017 002DE7C5 - H3000UTL Control File
CM 0090 00A5C758 - Channel Interface Code
ME 0045 00457241 - Master Processor Code
MM 0053 00583884 - Master Processor Code
NE 0045 00457241 - Network Interface (Token Ring etc.)
NM 0053 00583884 - Network Interface Code
PA 0008 00081F85 ...................File System, TDF's Etc..
PE 0007 0006F427 ...................File System, TDF's Etc..
P3 0008 00073B0D ...................File System, TDF's Etc..

** 005E <<BLOCKS FREE